Last edited by Nesho
Thursday, October 8, 2020 | History

2 edition of Pulse transition duration measurements and standards at NBS--1975 to 1988 found in the catalog.

Pulse transition duration measurements and standards at NBS--1975 to 1988

Pulse transition duration measurements and standards at NBS--1975 to 1988

  • 139 Want to read
  • 16 Currently reading

Published by U.S. Dept. of Commerce, Technology Administration, National Institute of Standards and Technology in Gaithersburg, Md .
Written in English

    Subjects:
  • United States. -- National Bureau of Standards.,
  • Pulse-duration modulation.

  • Edition Notes

    StatementW.L. Gans, ... [et al.].
    SeriesNISTIR -- 6550.
    ContributionsGans, W. L., National Institute of Standards and Technology (U.S.)
    The Physical Object
    FormatMicroform
    Paginationx, 118 p.
    Number of Pages118
    ID Numbers
    Open LibraryOL17704606M

    NBS STANDARD FREQUENCY TIME SERVICES AND Radio Stations WWV WWVH WWVB WWVL U.S. DEPARTMENT OF COMMERCE Alexander B. Trowbridge, Acting Secretary NATIONAL BUREAU OF STANDARDS A. V. Astin, Director MISCELLANEOUS PUBLICATION - EDITION Issued For sale by the Superlntendent of Documents, US. Government Prlntlng OfficeFile Size: 1MB.   Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time. Sci. Rep. 6, ; doi: /srep ().Cited by:

    CALIBRATION STANDARDS To make accurate measurements with any instrument, it is mandatory that it be calibrated against national standards. An oscilloscope makes two-dimensional measurements of voltage versus time. Thus, it must be calibrated with both voltage and time standards. The transient response should be checked using very fast pulse.   Pulse rate is a measure of the number of heartbeats per unit of time and it is typically expressed as heartbeats per minute (BPM). It varies based on the body's requirement for oxygen, and as such the pulse rate is at its highest during periods of exercise and at its lowest during sleep. Resting Pulse Rate 1. What Is Resting Pulse Rate?

    The vertical scale of the radar profile is in units of two-way travel time, the time it takes for an EM wave to travel down to a reflector and back to the surface. The travel time may be converted to depth by relating it to on-site measurements or assumptions about the velocity of the radar waves in the subsurface materials. The pressure pulse testing with multiple frequencies is useful in parameters quantitatively, when the radius of cyclic influence is covered by the sourced frequencies. By processing the time series pressure data effectively, the amount of both the time and frequency and the mechanic precision of the measurement device. The Size: 5MB.


Share this book
You might also like
basic teachings of Oomoto.

basic teachings of Oomoto.

Carbon, nitrogen and microbial colonization of volcanic debris on Mt. St. Helens

Carbon, nitrogen and microbial colonization of volcanic debris on Mt. St. Helens

Justicia Sect. Harniera (Acanthaceae) in tropical Africa

Justicia Sect. Harniera (Acanthaceae) in tropical Africa

True North Strong and Free?

True North Strong and Free?

Application of a distributed routing algorithm to a packet-switched communications network

Application of a distributed routing algorithm to a packet-switched communications network

Stratigraphy and depositional environment of Greenhorn limestone (Upper Cretaceous) of Kansas

Stratigraphy and depositional environment of Greenhorn limestone (Upper Cretaceous) of Kansas

Punjabis in Nottingham.

Punjabis in Nottingham.

Intellectual capital

Intellectual capital

history of the Patna College, 1863-1963

history of the Patna College, 1863-1963

sacrifice of man.

sacrifice of man.

Look Back in Love

Look Back in Love

The Poor boys pocketbook, or, Double primer

The Poor boys pocketbook, or, Double primer

pre-conquest church in England

pre-conquest church in England

Sony A500/A550

Sony A500/A550

Selected poems [of] Pierre Reverdy

Selected poems [of] Pierre Reverdy

The sociology of the economy

The sociology of the economy

Pulse transition duration measurements and standards at NBS--1975 to 1988 Download PDF EPUB FB2

The techniques employed by NBS from the mid 70s through for the calibration of the pulse transition duration (TD) of a fast, step-like, electrical pulse ge. The techniques employed by NBS from the mid 70s through for the calibration of the pulse transition duration (TD) of a fast, step-like, electrical pulse ge.

Pulse Transition Duration Measurements and Standards at NIST -- to Author: W L. Gans, N. Nahman, J R. Andrews, E E. Baldwin. Get this from a library. Pulse transition duration measurements and standards at NBS to [W L Gans; National Institute of Standards and Technology (U.S.);].

Measurement of Pulse and Transition Characteristics Open Live Script This example shows how to analyze pulses and transitions and compute metrics including rise time, fall time, slew rate, overshoot, undershoot, pulse width, and duty cycle. The performance of the proposed procedure has been tested on 10 subjects over a period of 4 weeks.

The results showed that the measurement differences were mmHg ± mmHg, and mmHg ± mmHg for systolic and diastolic blood pressure, : Hin-Wai Lui, King-Lau Chow. Period is the duration between the first transition of the current pulse and the first transition of the next pulse.

View the period of each pulse. View the period of each pulse. Using a tape measure, I find that my earlobe is about 12 inches (30cm) from my heart, and my fingertip is about 36 inches (90cm) from my heart.

The difference between the two is 24 inches (60cm), and the Pulse Transit Time value is 16mS. So that means that it took my pulse wave 16mS to travel 24 inches.

Pulse Transit Time. Best Practices for Making the Most Accurate Radar Pulse European Microwave 1. Transition duration Pulse top Pulse base Single positive-going transition and the illustration of 10%, 50% and 90% reference levels Best Practices for Making the Most Accurate Radar Pulse Measurements.

Abstract: This standard presents approximately terms, and their definitions, for accurately and precisely describing the waveforms of pulse signals and the process of measuring pulse signals. Algorithms are provided for computing the values of defined terms that describe measurable parameters of the waveform, such as transition duration, state level, pulse amplitude, and.

The Measurement and Deconvolution of Time Jitter in Equivalent-Time Waveform Samplers. The national standard of transition duration of pulse parameter in China is ps.

The standard Author: William Gans. Evaluation of short pulse, short recording measurements. It is a well-known fact that thermal measurements are excessively time consuming. The usual waiting time to reach the steady state is normally 5–30 minutes, which is prohibitive for production by: 6.

Mostly, the pulse rate and heart rate are equal but in case of premature beats or atrial fibrillations, the heart rate may be more than the pulse rate The difference is called the pulse-rate deficit.

In adults, the normal pulse appears at regular intervals and has a rate between per min. T-scanner for measuring pulse durations Article (PDF Available) in Optical and Quantum Electronics 28(9) September with 12 Reads How we measure 'reads'. The Kolsky bar, also known as the split Hopkinson pressure bar (SHPB), originally developed by Kolsky [1, 2] has been used by many investigators to obtain dynamic compression properties of solid technique has evolved [] since its development in the middle part of the 20th testing brittle materials, researchers have used the Kolsky bar to obtain dynamic, uniaxial Cited by: PULSE Reflex™ real‐time measurements are designed to take advantage of Brüel&Kjær’s unique coverage of the complete measurement chain, from transducers and front‐end hardware to data acquisition, analysis and reporting.

The emphasis is on scalability, from small (single‐module) systems to. Pulse transit time (PTT) is the time it takes for the pressure or flow wave to propagate between two arterial by: The current criterion standard for measuring inspiratory effort, esophageal manometry, is an invasive procedure that young patients find intolerable.

Inspiratory effort can also be assessed noninvasively by measuring the pulse transit time (PTT). PTT is the time the pulse wave (PW) takes to travel between two arterial sites (normally heart to finger).Cited by: Methods.

A Magstim Bistim 2 stimulator was used to produce TMS pulses of two distinct durations. For either pulse duration we measured, in healthy volunteers, resting and active motor thresholds, recruitment curves of motor evoked potentials in relaxed and contracting hand muscles as well as contralateral (cSP) and ipsilateral (iSP) cortical silent by: The PULSE65 is an authorized monthly magazine for service members and beneficiaries serving in the Republic of South Korea and the Pacific Rim under civilian enterprise printing contract with.

Pulse Transit Time (PTT), Pulse Wave Velocity (PWV) and Pulse Wave Amplitude (PWA) To measure pulse transit time, record the onset of the R-wave with an ECGC amplifier and record the pulse waveform at the fingertip using a TSD and the. Some studies have examined the relationship between measurement duration and the accuracy of pulse-counting.

A representative study by Jones () quantified the errors of pulse-counting at 15, 30 and 60 s. In that study, 58 nurses and 30 nursing students counted human pulse rates by radial palpation, which were then compared with the rates Cited by: 7.

Pitson DJ, Sandell A, van den Hout R, Stradling JR Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea.

Eur Respir J 8: – CASCited by:   New to Labview. I'm trying to measure pulse duration of a single, Power- On-Reset, pulse using waveform data. The Pulse measurements VI requires two consecutive mid ref level crossings in the same direction.

I have only one positive going mid ref level crossings & one negative in the waveform data. Am I missing something easy in the Waveform Measurements palette or do I .Wastewater Flow Measurement Wastewater Flow Measurement()_AF.R4 Effective Date: Aug time of measurement.” and “This is due to the variation of the C value American Society of Testing Materials, Annual Book of ASTM Standards, Volume 11 - Water, American Society of Testing Materials: Philadelphia.